Skip to main content

Table 2 Spearman's correlation between PDA diameters, pulmonary artery, and aortic diameters

From: Diagnostic performance of 320 cardiac MDCT angiography in assessment of PDA either isolated or associated with duct dependent congenital heart disease

 

Spearman's correlations

Size of aortic end (mm)

Size of pulmonary end (mm)

Length of PDA (mm)

R

P value

R

P value

R

P value

Diameter of MPA (mm)

0.064

0.752

0.002

0.992

− 0.451

0.018*

Diameter of RPA (mm)

0.109

0.574

− 0.162

0.409

− 0.295

0.120

Diameter of LPA (mm)

− 0.193

0.307

− 0.073

0.708

− 0.405

0.027*

Diameter of descending aorta (mm)

− 0.011

0.954

− 0.103

0.594

− 0.167

0.378

Diameter of aortic isthmus (mm)

0.004

0.984

− 0.140

0.470

0.021

0.914

  1. * significant p value (< 0.05)