Skip to main content

Table 1 The calculated prenatal MRI and US sensitivity, specificity and accuracy for holoprosencephaly, corpus callosum abnormalities, posterior fossa anomalies, and total midline cerebral anomaly cases

From: The prevalence and the adding value of fetal MRI imaging in midline cerebral anomalies

Diagnosis

Prenatal MRI

US

Sensitivity

Specificity

Accuracy

Sensitivity

Specificity

Accuracy

Holoprosencephaly

100%

100%

100%

88.9%

100%

97.3%

Corpus callosum abnormalities

100%

100%

100%

66.67%

100%

86.49%

Posterior fossa anomalies

91.67%

100%

97.30%

41.67%

92.59%

76.92%

Total

97.3%

100%

98.72%

56.76%

95.35%

77.50%