From: Role of adding T2 mapping sequence to the routine MR imaging protocol in the assessment of articular knee cartilage in osteoarthritis
Parameter
TP
TN
FP
FN
Accuracy(a)
Sensitivity
Specificity
PPV(a)
NPV(a)
Routine MRI
22
20
0
8
94.7
73.3%
100%
63.1%
T2 value (ms)
29
18
2
1
91.3
96.7%
90.0%
70.7%
99.1%