From: Role of ultrasonography in screening of spinal dysraphism in infants at risk
Type of spinal dysraphism | MRI | Ultrasound | Test value | P value | Kappa agreement (95% CI) |
---|---|---|---|---|---|
No. (%) | No. (%) | ||||
Segmentation/vertebral spine anomalies | |||||
No | 13 (65.0%) | 16 (80.0%) | 1.129* | 0.288 | 0.634 (0.279 to 0.989) |
Yes | 7 (35.0%) | 4 (20.0%) |