Skip to main content

Table 4 Sensitivity, specificity, PPV, NPV and accuracy of TPUS in relation to pelvic MRI

From: Role of transperineal ultrasound in evaluation of patients with perianal inflammatory disorders

 

Site of the internal opening

Abscesses

Horseshoe collections

Side branches

Supralevator extension

Value (%)

95% CI

Value (%)

95% CI

Value (%)

95% CI

Value (%)

95% CI

Value (%)

95% CI

Sensitivity

91.30

71.96–98.93

33.33

0.84–90.57

100.00

54.07–100.00

50.00

6.76–93.24

33.33

0.84–90.57

Specificity

57.14

18.41–90.10

100.00

87.23–100.00

100.00

85.75–100.00

92.31

74.87–99.05

88.89

70.84–97.65

Positive Predictive Value

87.50

74.67–94.32

100.00

 

100.00

 

50.00

16.07–83.93

25.00

4.64–69.52

Negative Predictive Value

66.67

31.47–89.70

93.10

85.85–96.78

100.00

 

92.31

81.74–96.99

92.31

84.21–96.43

Accuracy

83.33

65.28–94.36

93.33

77.93–99.18

100.00

88.43–100.00

86.67

69.28–96.24

83.33

65.28–94.36