Table 3 Accuracy, sensitivity, specificity, PPV, NPV of sonographic parameters

From: Evaluation of sensitivity and accuracy of maternal serum alpha fetoprotein to the diagnosis of open spina bifida in comparison with sonographic findings of open spina bifida and Chiari II malformation in pregnant women

 

OSB

Positive

Negative

Accuracy

Sensitivity

Specifity

PPV

NPV

Rised AFP

       

Positive

4

51

0.073

0.073

–

1.00

0.00

Negative

0

0

     

Normal IT

       

Positive

0

51

1.00

1.00

1.00

1.00

1.00

Negative

4

0

     

Decreased CM

       

Positive

4

0

1.00

1.00

1.00

1.00

1.00

Negative

0

51

     

Increased BS

       

Positive

2

0

1.00

1.00

1.00

1.00

1.00

Negative

0

51

     

Decreased BSOB

       

Positive

2

0

1.00

1.00

1.00

1.00

1.00

Negative

0

51

     

Increased BS/BSOB

       

Positive

2

0

1.00

1.00

1.00

1.00

1.00

Negative

0

51

     

BPD decrease

       

Positive

0

0

0.927

–

0.927

0.00

1.00

Negative

4

51

     

Ventriculomegalia

       

Positive

2

2

0.945

0.667

0.962

0.5

0.98

Negative

1

50