Skip to main content

Table 1 The parameters of MRI protocol

From: Phase-contrast magnetic resonance imaging in evaluation of hydrocephalus in pediatric patients

Sequences

Parameters

Routine MRI sequences:

TR/TE 400–600/15–25

Multiplanar T1WFSE

NEX 2

 

FA1/10

FOV 240 mm

Matrix 224 × 384

Multiplanar T2WFSE

TR/TE 5000/105

NEX 2

FA 1/10

FOV 240 mm

Matrix 224 × 384

Axial FLAIR WIS

TR/TE 11,000/140

TI 2800 ms

Axial DWI

TR/TE 3700/108

Mid sagittal steady-state free precession (SSFP) sequence

Thin cuts (3D-DRIVE) (for better assessment of CSF flow void sign along aqueduct of Sylvius)

Two-dimensional cine phase-contrast MRI sequence (2D cine PCMRI); Sagittal and axial images

Cardiac gating

Flip angle: 10°

TR/TE: 25/3.4

Section thickness: 1 mm

Field of view: 180 mm

Matrix size: 128 × 512