Skip to main content

Table 9 Sensitivity, specificity of MR neurography based on electrophysiological studies in the diagnosis of lumbosacral radiculo-plexopathy

From: Role of magnetic resonance neurography in assessment of lumbosacral radiculo-plexopathy: correlation with electrophysiological studies

MR neurography

Electrophysiological studies

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

Accuracy (%)

Normal

Abnormal

Patients (n = 50)

(n = 10)

(n = 40)

Normal

4 (40%)

1 (2.5%)

97.5

40.0

86.67

80.0

86.0

Abnormal

6 (60%)

39 (97.5%)

  1. PPV positive predictive value, NPV negative predictive value