Skip to main content

Table 4 The relation between HRUS and gold standard in detection of injury

From: Diagnostic performance of high-resolution ultrasound in pre- and postoperative evaluation of the hand tendons injuries

  Gold standard P value
Tendon Injury Intact tendon
Count % Count %
HRUS
 Injury 17 100 0 0 < 0.001
 Intact 0 0 13 100