From: Prediction of local breast cancer recurrence after surgery: the added value of diffusion tensor imaging
Measurement
DCE MRI alone (%)
DCE MRI with DTI (%)
Sensitivity
88.6
100
Specificity
88.1
90.5
Positive predictive value
86.1
89.7
Negative predictive value
90.2
Accuracy
88.3
94.8
F1 score
87.3
94.6
MCC
76.5
90.1