Skip to main content

Table 5 Comparison of diagnostic value of conventional MRI and diagnostic value of combined DWI and MRI

From: Diffusion‐weighted imaging and conventional magnetic resonance imaging for detection of non-palpable undescended testis

 

Diagnostic value of conventional MRI

Diagnostic value of combined DWI and MRI

Statistic

Value (%)

95% CI (%)

Value (%)

95% CI (%)

Sensitivity

85.71

67.33–95.97

92.86

76.50–99.12

Specificity

100

35.88–99.58

100

54.07–100

Positive predictive value (PPV)

100

79.94–99.31

100

Negative predictive value (NPV)

60

32.03–76.83

75.00

44.10–91.94

Accuracy

88.23

68.94–95.05

94.12

80.32–99.28