Skip to main content

Table 5 Agreement (sensitivity, specificity, and accuracy) for LCL (n = 16)

From: Value and imaging findings of the magnetic resonance in the posterolateral corner complex injuries of the knee

LCL Surgical Sensitivity Specificity PPV NPV Accuracy
Negative (n = 10) Positive (n = 6)
No. % No. %
MRI
Negative 0 0.0 0 0.0 100.0 0.0 37.50 37.50
Positive 10 100.0 6 100.0      
χ2 (p)     
  1. χ2 chi-square test, p p value for association between different categories, PPV positive predictive value NPV negative predictive value