Skip to main content

Table 1 Scan parameters of the two groups

From: Evaluation of high temporal resolution magnetic resonance imaging of the liver with gadoxetate disodium in combination with compressed sensing and parallel imaging under single breath-holding using a 1.5-T magnetic resonance system

Parameter

6-s scan (triple arterial phase)

10-s scan (double arterial phase)

Field of view (mm2)

320 × 320

320 × 320

Slice thickness (mm)

4

4

Matrix

256 × 192

256 × 192

Bandwidth (Hz/pixel)

488.281

488.281

Repetition time (msec)

5.546

5.546

Echo time (msec)

1.416

1.416

Flip angle (degree)

12

12

CS factor

2.0

2.0

Phase ARC

2.0

2.0

Slice ARC

2.0

1.2

Acquisition time (sec)

6

10

  1. CS, compressed sensing, ARC, auto-calibrating reconstruction for Cartesian imaging