Skip to main content

Table 3 Radiation dose rate, elapsed time, and cumulative dose due to staff exposure to thyroid cancer patients treated with RAI-131 for the Group-B

From: Estimation of effective doses to whole-bodies and hands of facilitating staff from radioiodine-131 ablation therapy patients

Phase

Range, average dose rate (μSv/h)

Elapsed time, (min)

Average accumulative dose, (μSv)

Dose reduction factor (FR)

Γ,( μSv m2/MBq h)

2 h

(73.7–101.9)

1.3 ± 0.2

1.9 ± 0.6

0.999

0.019 ± 0.004

87.8 ± 14.0

    

Second day

(16.5–34.7)

1.5 ± 0.3

0.6 ± 0.4

0.998

0.006 ± 0.002

25.6 ± 9.0

    

Third day

(11.3–4.9)

2.0 ± 0.1

0.3 ± 0.1

0.997

0.002 ± 0.001

8.1 ± 5.0

    

Fourth day

(1.5–5.3)

2.2 ± 0.5

0.1 ± 0.1

0.995

0.001 ± 0.001

3.4 ± 2.0

    

Fifth day

(3.6–1.2)

2.5 ± 0.9

0.1 ± 0.1

0.993

0.001 ± 0.001

2.4 ± 1.0